First-aid measures

IF SWALLOWED: Rinse mouth. Treat symptomatically.

IF INHALED: Move person to fresh air. If breathing is laboured, administer oxygen. If symptoms develop, obtain medical attention.

IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P337+P313: If eye irritation persists: Get medical advice/attention.

IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. P363: Wash contaminated clothing before reuse.

Fire-fighting measures

- Suitable extinguishing media:

Non-flammable / Non-combustible. As appropriate for surrounding fire.

- Unsuitable extinguishing media:

None known.

- Special hazards arising from the substance or mixture:

Thermal decomposition products include: Carbon monoxide, Carbon dioxide, and hydrogen fluorides

- Advice for fire fighter: A self contained breathing apparatus and suitable protective clothing should be worn in fire conditions

Accidental release measures

- Personal precautions:

Wear protective gloves/eye protection. Avoid breathing mist/vapors/spray.

- Environmental precautions:

Avoid run off to waterways and sewers

- Methods and material for containment and cleaning up: Transfer to a container for disposal or recovery

Handling and storage

- Precautions for safe handling:

Avoid contact with skin and eyes. Wear protective gloves/eye protection/face protection. Wash hands and exposed skin thoroughly after handling. Avoid breathing vapors.

- Conditions for safe storage, including any incompatibilities: Store at room temperature. Keep only in original or other compatible container.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not Regulated
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Not Regulated
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not Regulated
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
3334
Shipping information
Proper shipping name and description:
Aviation regulated liquid, n.o.s. (Sevoflurane Related Compound B)
Chemical name:
Sevoflurane Related Compound B
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

1. Technical protection measures: Use only with adequate ventilation or closed system ventilation. Use closed dosing, transfer, sampling and application systems including connectors. Formulate in enclosed or ventilated mixing vessels.

2. Organisational protection measures: None specified

3. Hand protection: Wear protective gloves. (Neoprene)

4. Feet protection: None specified

5. Body protection: None specified

6. Eye protection: Wear protective eyewear (goggles, face shield, or safety glasses)

7. Respiratory protection: Not normally required. In poorly ventilated areas or confined spaces, use an airline respirator or self-contained breathing apparatus.

Stability and reactivity

1. Reactivity

: Stable under normal conditions

2. Chemical stability

: Stable

3. Possibility of hazardous reactions

: None anticipated.

4. Conditions to avoid: Incompatible materials

5. Incompatible materials:

Strong oxidising agents, Alkalis and alkali metals, Aluminum, Zinc, Alkaline earth metals

6. Hazardous decomposition products: Thermal decomposition products include: Carbon monoxide, Carbon dioxide, and hydrogen fluorides.

Disposal considerations