Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
September 03, 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no
Specific details on test material used for the study:
No further preliminary treatment such as drying or milling was performed.
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Preliminary test

The test item could not be ignited with a flame. The test item melted. The performance of the main test was not necessary.

Interpretation of results:
GHS criteria not met
Conclusions:
The substance has not to be classified as flammable solid.
Executive summary:

A preliminary test according to Regulation (EC) No 440/2008 EU Method A.10 was performed to determine the flammability of the test substance. In a preliminary test the burning behaviour over a distance of 200 mm is measured. One end of the pile is ignited. The test item could not be ignited with a flame. The test item melted. The performance of the main test was not necessary. The substance has not to be classified as flammable solid.

Endpoint:
pyrophoric solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Endpoint:
self-heating substances / mixtures
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is completely molten at 160°C
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water
Endpoint:
flammable gases
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a solid
Endpoint:
pyrophoric liquids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a solid

Description of key information

The substance has not to be classified as flammable gas, flammable liquid, flammable solid, flammable in contact with water, flammable aerosol, pyrophoric solid, pyrophoric liquid or self-heating substance.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Flammable gases(reference 4.13-2)

The test item is a solid at ambient conditions. This hazard class is only applicable for gases. Thus, the substance was not considered for classification as flammable gas.

Flammable liquid (reference 4.11-1)

In accordance with column 2 adaptation statement of Annex VII Regulation (EC) No 1907/2006 (REACH), the determination of the flash point (as required in section 7.9 of Annex VII) does not need to be conducted as the substance is a solid at ambient conditions.

Flammable solids(reference 4.13-1)

A preliminary test according to Regulation (EC) No 440/2008 EU Method A.10 was performed to determine the flammability of the test substance. In a preliminary test the burning behaviour over a distance of 200 mm is measured. One end of the pile is ignited. The test item could not be ignited with a flame. The test item melted. The performance of the main test was not necessary. The substance has not to be classified as flammable solid.

Pyrophoric solids(reference 4.13-4)

In accordance with section 2.9.4 Annex I of Regulation (EC) No 1272/2008 and ECHA guidance on the application of CLP Criteria section 2.10.4.2 the classification procedure for pyrophoric solids need not be applied when experience in manufacturing or handling shows that the substance or mixture does not ignite spontaneously when coming into contact with air at normal temperatures. Based on the experience in handling and use the substance is not known to ignite spontaneously when coming into contact with air at normal temperatures. Thus, no study was conducted and the substance was not considered for classification as pyrophoric solid.

Pyrophoric liquids(reference 4.13-3)

The test item is a solid at ambient conditions. This hazard class is only applicable for liquids. Thus, the substance was not considered for classification as pyrophoric liquid.

Substances which, in contact with water, emit flammable gases(reference 4.13-6)

In accordance with column 2 of REACH Annex VI and with Regulation (EC) No 1272/2008 Annex I section 2.12.4.1 the classification procedure for this hazard class need not to be applied. Based on the experience in handling and use the substance does not react with water and in addition the test substance is not pyrophoric. Thus, no study was conducted and the substance was not considered for classification.

Self-heating substances and mixtures(reference 4.13-5)

According to section 2 of REACH Annex XI, the test on self-heating substances does not need to be conducted because there are no chemical groups present in the molecule associated with self heating properties. Therefore, no test on self-heating is required.

Flammable Aerosols

Section 2.4.2 of Guidance on the application on the CLP Criteria state as follows:

“Aerosols, this means aerosol dispensers, are any non-refillable receptacles made of metal, glass or plastics and containing a gas compressed, liquefied or dissolved under pressure, with or without a liquid, paste or powder, and fitted with a release device allowing the contents to be ejected as solid or liquid particles in suspension in a gas, as a foam, paste or powder or in a liquid state or in a gaseous state." Thus, as the substance does not meet the definition for aerosol, the test for aerosols was waived. Consequently the substance has not to be considered for classification for this hazard class.

 

Conclusion

In conclusion the substance has not to be considered as flammable gas, flammable liquid, flammable solid, flammable in contact with water, flammable aerosol, pyrophoric solid, pyrophoric liquid or self-heating substance.

Justification for classification or non-classification

Classification, Labelling, and Packaging Regulation (EC) No. 1272/2008

In accordance with Annex I Section 2.2, Section 2.3, Section 2.6, Section 2.7, Section 2.9, Section 2.10 Section 2.11, Section 2.12 of Regulation (EC) No. 1272/2008, as amended for the twelfth time in Regulation (EU) No 2019/521, and UN GHS Rev 7 (2017) the test item has not to be classified as, flammable liquid, readily combustible solid in class 4 Division 4.1, self-heating substance in Class 4 Division 4.2, substances which in contact with water emit flammable gases in Class 4 Division 4.3, pyrophoric liquid, pyrophoric solid in class 4 Division 4.2, flammable gases in class 2 or as aerosol in class 2.