Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-10-02 to 2018-11-14
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
121 °C
Atm. press.:
1 013 hPa

Preliminary test

Results of the preliminary test are summarized in Table 1.

Table 1: Results of the preliminary test

Weight / g

Flash point / °C measured

Atmospheric pressure / hPa

Flash point / °C corrected

85.06

120.5

1015.6

120.4

The data point was determined with a heating rate of 8.5 K/min, as proposed in DIN EN ISO 2719.

Main test

Results of the main test are summarized in Table 2.

Table 2: Results of the main test

Weight / g

Flash point / °C measured

Atmospheric pressure / hPa

Flash point / °C corrected

84.80

121.5

1015.0

121.5

85.10

123.5

1015.0

123.5

The data points were determined with a heating rate of 5.5 K/min.

The lowest flash point corrected to 1013 hPa was rounded down to the next lower 0.5 °C: 121.0 °C.

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test item is 121.0 °C under atmospheric conditions (1013 hPa).
Executive summary:

The flash point of the test item was determined according to EU Method A.9. The flash point of the test item is 121.0 °C under atmospheric conditions (1013 hPa).

Description of key information

The flash point of the test item is 121.0 °C under atmospheric conditions (1013 hPa).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
121 °C

Additional information