Registration Dossier

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
according to guideline
Guideline:
other: ASTM E794
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
differential scanning calorimetry
Key result
Melting / freezing pt.:
> 108 - < 112 °C
Atm. press.:
ca. 1 atm
Decomposition:
no
Conclusions:
Melting point range is is 108 – 112 °C ,110 °C (DSC – ASTM E794)

Description of key information

110 °C (DSC – ASTM E794) Melting Range 108 to 112°C

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
110 °C

Additional information