Registration Dossier

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
DIN EN 14522, Method P (Determination of the auto ignition temperature of gases and vapours)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid
Specific details on test material used for the study:
OMAX (2-(methoxymethyl)-3-methyl-aniline) destilliert
Batch No.: 39460/132-Fraktion 2-6

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
394 °C
Atm. press.:
1 013.25 hPa

Any other information on results incl. tables

Results

Test run no.

Lowest temperature leading to autoignition

°C

Quantitity of sample

ml

Ignition delay time

sec

1

401

0.09

7

2

400

0.09

8

3

401

0.09

8

4

401

0.09

9

Autoignition temperature (corrected)*: 394 °C

* The corrected auto ignition temperature is calculated by subtracting 1.5% of the lowest experimentally observed auto ignition temperature (given in units of °C) in order to take into account all uncertainties (calibration, temperature measuring system, amount of substance, etc.). This value is then rounded to the next 1 K.

Electrical and non-electrical equipment, which may be in contact with explosive mixtures of the test substance and air, has to be of a temperature class T2 or higher.

Applicant's summary and conclusion