Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove the affected person to fresh air. Symptomatic
treatment.
Emergency measure - Eyes: Rinse with plenty of water and seek medical attention.
Emergency measure - Skin: Remove contaminated clothing, wash with soap and water and
seek medical attention.
Emergency measure - Ingestion: Drink plenty of wtaer, seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Water spray, foam, dry powder and carbon dioxide may be
used.

Product arising from burning: Products of combustion may contain oxides of carbon, sulfur
and antimony, hydrogen fluoride and soot.

Product determined by test: N

Protective equipment: A self-contained breathing apparatus should be worn.

Accidental release measures

Emergency measures in case of spillage: Wear suitable protective clothing, see 2.3.1. Do not allow
substance/preparation to enter drains. Soak up using
suitable absorbant material, collect residues and place into
a labelled waste container for disposal by incineration.

Handling and storage

Handling: Observe the usual precautions for handling organic
chemicals. Ensure good local exhaust ventilation. Strictly
avoid contact with skin and eyes by the correct use of
suitable protective clothing, gloves and goggles. Do not
expose to light. Avoid any possible environmental release.

Storage: Store in tightly closed containers in cool conditions away
from food or foodstuffs. Do not expose to light.

Packaging of the substance and or preparation: 25 kg polyethylene drums.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport code: UN 3082
Transport: Transport in tightly closed containers away from food or
foodstuffs. Containers must meet international transport
requirements.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: There is a possibility of hydrolysis to form hydrogen
fluoride.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for recycling is not possible.

Industry - Possibility of neutralisation: React with corresponding epoxy resin component until fully
cured. (A634)

Industry - Possibility of destruction: controlled discharge: Not recommended for the substance. Disposal by controlled
landfill is possible after reaction with epoxy resin until
fully cured.(A650)

Industry - Possibility of destruction - incineration: Incinerate at above 1200 deg C in a facility equipped to
remove oxides of sulfur, hydrogen fluoride and compounds of
antimony. (A663)

Industry - Possibility of destruction - water purification: Not recommended.

Public at large - Possibility of recovery/recycling: The substance will only enter the public domain as part of
an article. Recovery from articles is not feasible.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction - others: The substance will only enter the public domain as part of
an article. Disposal as domestic waste is possible.