Registration Dossier

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14 - 17 Jan 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report Date:
2019

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
395 °C
Atm. press.:
>= 997 - <= 1 014 hPa

Any other information on results incl. tables

Series

Temperature (°C)

Series 1

397

Series 2

396

Series 3

399

 

Atmospheric pressure during the measurement:

2019-01-14: 1007 hPa

2019-01-15: 1014 hPa

2019-01-16: 1007 hPa

2019-01-17: 997 hPa

 

Atmospheric pressure and relative humidity of the air are of minor effects on measured auto-ignition temperatures at temperatures above 150 °C.

The lowest value out of these series is rounded down to the next value which may be divided by 5 (yielding an integer).

 

The test item has an auto-ignition temperature of 395 °C according to the definition in the annex of Council Regulation (EC) No 440/2008 of 30 May 2008, method A. 15.