Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test O.2 (Test for oxidizing liquids)
Principles of method if other than guideline:
The test is carried out according to “34.4.2 Test O.2: Test for oxidizing liquids” in “UN, Recommendations on the transport of dangerous goods - Manual of Tests and Criteria (ST/SG/AC.10/11/Rev.5)”. This test method is designed to measure the potential for the liquid sample to increase the burning rate or burning intensity of a combustible substance when the two are thoroughly mixed or to form a mixture which spontaneously ignites. The liquid sample is mixed in a 1 to 1 ratio, by mass, with fibrous cellulose, the mixture heated in a pressure vessel and the rate of pressure rise determined, and compared with another mixture from a control item and fibrous cellulose.
GLP compliance:
no
Sample tested:
other: The liquid sample is mixed in a 1 to 1 ratio, by mass, with fibrous cellulose
Parameter:
mean pressure rise time
Result:
> 60 s
Conclusions:
The sample is not an oxidizing liquid substance.

Description of key information

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification