Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: UN Manual Test Methods 32.4
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
5-diethoxymethyl-1,3-benzodioxole
EC Number:
254-956-0
EC Name:
5-diethoxymethyl-1,3-benzodioxole
Cas Number:
40527-42-2
Molecular formula:
C12H16O4
IUPAC Name:
5-(diethoxymethyl)-2H-1,3-benzodioxole
impurity 1
Chemical structure
Reference substance name:
Piperonal
EC Number:
204-409-7
EC Name:
Piperonal
Cas Number:
120-57-0
Molecular formula:
C8H6O3
IUPAC Name:
1,3-benzodioxole-5-carbaldehyde
Specific details on test material used for the study:
Batch no.: 18030042
Appearance: colorless to pale yellow liquid
Purity: 99% (GC)
Homogeneity: homogeneous
Production date: 14. Mar. 2018
Expiry date: 14. Mar. 2019
Storage: Room Temperature (20 ± 5°C) store under inert gas in the dark

Results and discussion

Flash point
Key result
Flash point:
ca. 113.5 °C
Atm. press.:
ca. 101 325 Pa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
According to EU Method A.9, OPPTS 830.6315 and UN Manual Test Methods 32.4, the flash point of the test item is 113.5°C at standard pressure.