Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
other: DIN 66165 (Particle size analysis - Sieving analysis)
GLP compliance:
no
Type of method:
sieving
No.:
#1
Size:
> 2 mm
Distribution:
0 %
No.:
#1
Size:
> 1.4 - <= 2 mm
Distribution:
0 %
No.:
#1
Size:
> 1 - <= 1.4 mm
Distribution:
0.1 %
No.:
#1
Size:
> 0.8 - <= 1 mm
Distribution:
0.1 %
No.:
#1
Size:
> 0.5 - <= 0.8 mm
Distribution:
10.4 %
No.:
#1
Size:
> 0.4 - <= 0.8 mm
Distribution:
23.3 %
No.:
#1
Size:
> 0.3 - <= 0.4 mm
Distribution:
30.4 %
No.:
#1
Size:
> 0.2 - <= 0.3 mm
Distribution:
24.3 %
No.:
#1
Size:
> 0.1 - <= 0.2 mm
Distribution:
10.5 %
No.:
#1
Size:
> 0.05 - <= 0.1 mm
Distribution:
0.9 %
No.:
#1
Size:
< 0.05 mm
Distribution:
0 %

Description of key information

The particle size distribution was determined according to DIN 66165: "Particle size analysis - Sieving analysis ":

Size of the sieve

%

>2 mm

0.0

>1.4 mm

0.0

>1 mm

0.1

>800 µm

0.1

>500 µm

10.4

>400 µm

23.3

>300 µm

30.4

>200 µm

24.3

>100 µm

10.5

>50 µm

0.9

<50 µm

0.0

Additional information