Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising liquids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the organic substance contains oxygen or halogen atoms which are chemically bonded only to carbon or hydrogen and hence, the classification procedure does not need to be applied
the study does not need to be conducted because the substance is flammable
Justification for type of information:
The liquid substance is highly flammable according to flash point information and GHS criteria provided, in addition, All of the oxygen amount present in the substance are bound to carbon or hydrogen. the substance doesn't contain fluorine and very small amount of organic chlorides (360 ppm bounded to hydrocarbons).

Data source

Materials and methods

Test guideline
Qualifier:
no guideline required
Principles of method if other than guideline:
An assement was performed to determin the oxidising potentioal of the substance based on the composition and molecular structure of its components
GLP compliance:
no

Test material

Constituent 1
Reference substance name:
Hydrocarbons from mixed waste plastics, thermo-mechanical depolymerization condensate
Molecular formula:
C5-C29
IUPAC Name:
Hydrocarbons from mixed waste plastics, thermo-mechanical depolymerization condensate
Test material form:
liquid
Details on test material:
Hydrocarbons from mixed waste plastics, thermo-mechanical depolymerization condensate. It is a complex combination of hydrocarbons as described in section one.

Results and discussion

Test results (Oxidising liquids)
Sample tested:
other:
Remarks:
the analysis was done based on the molecular structure of the substance and functional groups
Parameter:
other: the analysis was done based on the molecular structure of the substance and functional groups
Remarks on result:
other: the analysis was done based on the molecular structure of the substance and functional groups
Remarks:
the analysis was done based on the molecular structure of the substance and functional groups

Any other information on results incl. tables

All of the oxygen amount present in the substance are bound to carbon or hydrgen. In addition the substance doesn't contain fluorine and very small amount of organic chlorides ( 360 ppm). Therefore, it can be concluded that the substance does not have oxidising potential and does not require classification as an oxidising agent. Moreove, oxidizing stability according to EN ISO 12205 was not technically possible.

Applicant's summary and conclusion

Interpretation of results:
other: No oxidising properties
Conclusions:
It is concluded that the UVCB substance does not have oxidising potential and does not require classification as an oxidising agent.
Executive summary:

The oxidising properties of the substance were determined based an assessment of the composition of the substance and the molecular structure of its components. None of the components of the substance were found to have functional groups associated with oxidising potential. It was concluded that the test substance does not have oxidising potential and does not require classification as an oxidising agent.