Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 949-054-5 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Skin irritation / corrosion
Administrative data
- Endpoint:
- skin corrosion: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 01 - 24 August 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Remarks:
- Study was conducted in accordance with international guidelines and in accordance with GLP. All guideline validity criteria were met.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 018
- Report date:
- 2018
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
- Version / remarks:
- 29 Jul 2016
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.40 (In Vitro Skin Corrosion: Transcutaneous Electrical Resistance Test (TER))
- Version / remarks:
- Adopting the 27th time to technical progress the Dangerous Substances Directive 67/548/EEC, Annex V, part B40 and EC regulation No 440/2008 of 30 May 2008 laying down test methods pursuant to Regulation No 1907/2006 of the European Parliament and of the Council on REACH, 1st ATP, section B40.
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: MatTek test protocol “In vitro EpiDerm Skin Corrosion Test (EPI-200-SCT)”
- Version / remarks:
- 07 Nov 2014
- Deviations:
- yes
- Remarks:
- The formazan salt extraction period was extended up to 72 hours. According to an expert statement (from MatTek Corporation) this procedure does not have an impact on the outcome of the study.
- GLP compliance:
- yes (incl. QA statement)
Test material
- Reference substance name:
- Salts of 2-ethylhexyl phosphate esters with (Z)- octadec-9-enylamine
- EC Number:
- 949-054-5
- Molecular formula:
- not applicable, UVCB substance
- IUPAC Name:
- Salts of 2-ethylhexyl phosphate esters with (Z)- octadec-9-enylamine
- Test material form:
- liquid: viscous
Constituent 1
In vitro test system
- Test system:
- human skin model
- Source species:
- human
- Cell type:
- non-transformed keratinocytes
- Cell source:
- other: EpiDerm tissues supplied by MatTek Corporation, Slovakia.
- Justification for test system used:
- Guideline specific test system.
- Vehicle:
- unchanged (no vehicle)
- Details on test system:
- RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: EpiDerm
- Tissue batch number(s): 288647
- Production date: Not reported
- Shipping date: Not reported
- Delivery date: 21 Aug 2018
- Date of initiation of testing: 21 Aug 2018
TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: Room temperature ( 3 min exposure group) and 37 ± 1.5 ºC (60 min exposure group)
- Temperature of post-treatment incubation (if applicable): 37 ± 1.5 ºC
REMOVAL OF TEST MATERIAL AND CONTROLS
-Volume and number of washing steps: 20 times
- Observable damage in the tissue due to washing: No
- Modifications to validated SOP: No
MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- MTT concentration: 1 mg/mL
- Incubation time: 3 h incubation with MTT solution followd by 19 h extraction.
- Spectrophotometer: Microplate reader (Versamax®, Molecular Devices, SoftMax Pro Enterprise (version 4.7.1)) at 570 nm (OD570)
- Wavelength: 570 nm
- Filter: No
- Filter bandwidth: Not reported
- Linear OD range of spectrophotometer: Not reported
FUNCTIONAL MODEL CONDITIONS WITH REFERENCE TO HISTORICAL DATA
- Viability: Acceptable (2.097 ± 0.214). Acceptance criteria = 1.0 - 3.0.
- Barrier function: Acceptable (6.33 h). Acceptance criteria 4.77 - 8.72 h.
- Morphology: Acceptable.
- Contamination: Acceptable (sterile).
- Reproducibility: COV of mean replicates = < 30 %.
NUMBER OF REPLICATE TISSUES: 1
CONTROL TISSUES USED IN CASE OF MTT DIRECT INTERFERENCE
- Fresh tissues / killed tissues : N/A
- Procedure used to prepare the killed tissues (if applicable): N/A
- N. of replicates : N/A
- Method of calculation used: N/A
NUMBER OF INDEPENDENT TEST SEQUENCES / EXPERIMENTS TO DERIVE FINAL PREDICTION: 2
PREDICTION MODEL / DECISION CRITERIA (choose relevant statement)
- The test substance is considered to be corrosive to skin if the viability after 3 minutes exposure is less than 50%, or if the viability after 3 minutes exposure is greater than or equal to 50 % and the viability after 1 hour exposure is less than 15%.
- The test substance is considered to be non-corrosive to skin if the viability after 3 minutes exposure is greater than or equal to 50% and the viability after 1 hour exposure is greater than or equal to 15%.
- Justification for the selection of the cut-off point(s) if different than recommended in TG 431 and 439: N/A - Control samples:
- yes, concurrent negative control
- yes, concurrent positive control
- Amount/concentration applied:
- TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 50 µL
- Concentration (if solution): Unchanged - applied as supplied
VEHICLE
- Amount(s) applied (volume or weight with unit): N/A
- Concentration (if solution): N/A
- Lot/batch no. (if required): N/A
- Purity: N/A
NEGATIVE CONTROL
- Amount(s) applied (volume or weight): 50 µL
- Concentration (if solution): N/A
POSITIVE CONTROL
- Amount(s) applied (volume or weight): 50 µL
- Concentration (if solution): 8 N - Duration of treatment / exposure:
- 3 and 60 minutes
- Duration of post-treatment incubation (if applicable):
- Incubated in MTT medium for 3 hours and followed by an 19 h extraction in isopropanol.
- Number of replicates:
- 2 for each timepoint
Results and discussion
In vitro
Resultsopen allclose all
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- 3 minute exposure
- Value:
- 97.62
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- 60 min exposure
- Value:
- 100.04
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Other effects / acceptance of results:
- - OTHER EFFECTS:
- Visible damage on test system: No
- Direct-MTT reduction: No
- Colour interference with MTT: No
DEMONSTRATION OF TECHNICAL PROFICIENCY: Yes inc. certificate.
ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: The mean OD of the tissue replicates treated with the negative control is ≥ 0.8 and ≤ 2.8 for every exposure time.
- Acceptance criteria met for positive control: The mean viability of the tissue replicates treated with the positive control for 1 hour, is <15 % compared to the negative control.
- Acceptance criteria met for variability between replicate measurements: Coefficient of Variation (CV) in the range 20 – 100 % viability between tissue replicates is ≤ 30 %.
- Range of historical values if different from the ones specified in the test guideline:
Positive control: 3 min = 4.6 - 39.83 % viability, 60 min = 1.07 - 14.77 % viability (n=33).
Negative control: 3 min = 1.25-1.93 OD range, 60 min = 1.23-2.00 OD range (n=33)
Any other information on results incl. tables
Table.2 Viabilities for the negative control, positive control and test item
Treatment group |
Tissue no. |
Exposure interval (mins) |
OD 570 nm |
Mean OD of 3 wells (blank corrected) |
Mean OD of 2 tissues (blank corrected) |
SD (well 1-3) |
Mean relative viability (%) |
CV (%) |
||
Well 1 |
Well 2 |
Well 3 |
||||||||
Blank |
- |
3 |
0.038 |
0.038 |
0.038 |
|
||||
Negative control |
1 |
2.034 |
1.980 |
2.078 |
1.992 |
1.970 |
0.049 |
100.00 |
1.6 |
|
2 |
2.035 |
1.967 |
1.954 |
1.947 |
0.043 |
|||||
Positive control |
1 |
0.300 |
0.293 |
0.290 |
0.256 |
0.211 |
0.005 |
10.70 |
30.6 |
|
2 |
0.205 |
0.202 |
0.203 |
0.165 |
0.002 |
|||||
Test item |
1 |
2.073 |
1.994 |
2.013 |
1.989 |
1.923 |
0.041 |
97.62 |
4.8 |
|
2 |
1.867 |
1.911 |
1.908 |
1.857 |
0.024 |
|||||
Blank |
- |
60 |
0.038 |
0.038 |
0.038 |
|
||||
Negative control |
1 |
2.209 |
2.157 |
2.162 |
2.138 |
2.016 |
0.028 |
100.00 |
8.5 |
|
2 |
1.959 |
1.928 |
1.912 |
1.895 |
0.024 |
|||||
Positive control |
1 |
0.125 |
0.120 |
0.115 |
0.082 |
0.069 |
0.005 |
3.41 |
27.1 |
|
2 |
0.095 |
0.094 |
0.093 |
0.056 |
0.001 |
|||||
Test item |
1 |
2.088 |
2.051 |
2.059 |
2.028 |
2.017 |
0.020 |
100.04 |
0.8 |
|
2 |
2.037 |
2.063 |
2.033 |
2.006 |
0.016 |
Applicant's summary and conclusion
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- Under the conditions of this study the test substance is not considered to be corrosive.
- Executive summary:
OECD 431 (2018) - The skin corrosivity potential of the test item was assessed using an EpiDerm Reconstructed Human Epidermis (RHE) Model Kit in accordance with OECD guidance 431 and GLP.
Duplicate tissues were treated with the test item for exposure periods of 3 and 60 mins. At the end of the exposure period the test item was rinsed from each tissue before being loaded with MTT. After MTT loading each tissue was placed in 2 mL isopropanol for MTT extraction. After extraction, each tissue was pierced and the extraction solution aliquoted for absorbance measurements. Absorbency at 570 nm of each well was measured using a spectrophotometer.
The test item passed the MTT- and the colour interference pre-tests and all acceptability criteria were met. Exposure to the positive control induced a decrease in the relative absorbance as compared to the negative control, both for the 3 minutes exposure period (10.70%) and for the 1 hour exposure period (3.41%) thus confirming the validity of the test system and the specific batch of tissue models.
Mean viability of tissues exposed to the test substance after 3 and 60 minutes were 97.62 and 100.04 %, respectively.
Under the conditions of this study the test substance is not considered to be corrosive to the skin according to the Globally Harmonized Classification System and to the Regulation (EC) No. 1272/2008; relating to the Classification, Labelling and Packaging of Substances and Mixture.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.