Registration Dossier

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2001
Report date:
2001

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method C.4-D (Determination of the "Ready" Biodegradability - Manometric Respirometry Test)
Deviations:
yes

Test material

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
activated sludge, domestic, adapted
Duration of test (contact time):
28 d
Initial test substance concentrationopen allclose all
Initial conc.:
100 mg/L
Based on:
test mat.
Initial conc.:
> 50 - < 100 mg/L
Based on:
ThOD

Results and discussion

% Degradation
Key result
Parameter:
% degradation (O2 consumption)
Value:
0
Sampling time:
28 d

Applicant's summary and conclusion

Validity criteria fulfilled:
yes