Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
other: 92/69/EWG, A.6 (Kolben-Methode)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Deviations:
no
GLP compliance:
yes
Type of method:
flask method

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Water solubility
Water solubility:
ca. 972 g/L
Temp.:
20 °C
Remarks on result:
other: The pH was not measured.

Applicant's summary and conclusion

Conclusions:
In conclusion, the water solubility of the test item was higher than 100 g/L. The water solubility was calculated to be 972 g/L (mean value, 21 g/L standard deviation) at 20 °C +/- 1 °C.
Executive summary:

In conclusion, the water solubility of the test item was higher than 100 g/L. The water solubility was calculated to be 972 g/L (mean value, 21 g/L standard deviation) at 20 °C +/- 1 °C.