Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
partition coefficient
Type of information:
calculation (if not (Q)SAR)
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
accepted calculation method
Justification for type of information:
LogPow testing on the substance has been carried out. However, no peaks were detected; thus, no LogPow could be derived during the test. Therefore, EpiSuite calculations on all identified components in the UVCB substance (>1wt%) have then been carried out and used. The below smiles notations were used:
C(O)C(O)C(O)
OCC(O)COCC(O)C(O)
OCC(O)COCC(O)COCC(O)CO
C(O)C(O)C(OC(=O)CCCCCCCCCCC)
OCC(O)COCC(O)C(OC(=O)CCCCCCCCCCC)
OCC(O)COCC(O)C(OC(=O)CCCCCCCCCCCCC)
OCC(O)COCC(O)C(OC(=O)CCCCCCCCCCCCCCC)
OCC(O)COCC(O)C(OC(=O)CCCCCCCCCCCCCCCCC)
OCC(O)COCC(O)COCC(OC(=O)CCCCCCCCCCC)CO
OCC(O)COCC(OC(=O)CCCCCCCCCCC)C(OC(=O)CCCCCCCCCCC)
OCC(O)COCC(OC(=O)CCCCCCCCCCCCC)C(OC(=O)CCCCCCCCCCC)
OCC(O)COCC(OC(=O)CCCCCCCCCCCCCCC)C(OC(=O)CCCCCCCCCCC)
OCC(O)COCC(OC(=O)CCCCCCCCCCCCCCCCC)C(OC(=O)CCCCCCCCCCC)
OCC(O)COCC(OC(=O)CCCCCCCCCCCCCCCCC)C(OC(=O)CCCCCCCCCCCCC)
OCC(O)COCC(OC(=O)CCCCCCCCCCCCCCCCC)C(OC(=O)CCCCCCCCCCCCCCC)
OCC(O)COCC(OC(=O)CCCCCCCCCCCCCCCCC)C(OC(=O)CCCCCCCCCCCCCCCCC)
Qualifier:
no guideline followed
Principles of method if other than guideline:
EpiSuite Calculations. US EPA Epi Suite v4.0 has been used.
GLP compliance:
no
Other quality assurance:
other: Internal DHI QA
Type of method:
calculation method (fragments)
Partition coefficient type:
octanol-water
Specific details on test material used for the study:
Calculations have been carried out for all identified components (>1wt%) in the UVCB-substance.
Key result
Type:
log Pow
Partition coefficient:
>= 1.43 - <= 13.58
Temp.:
25 °C
pH:
ca. 7
Remarks on result:
other:
Remarks:
Limit of components present >1wt%
Conclusions:
According to EpiSuite (US EPA Epi Suite v4.0) calculations, the logPow was found to vary between 1.43 to 13.58 for all substances present in >1wt% in the UVCB-substance. The concentration weighted average was found at 3.36-5.79.
Executive summary:

According to EpiSuite ( US EPA Epi Suite v4.0) calculations, the logPow was found to vary between 1.43 to 13.58 for all substances present in >1wt% in the UVCB-substance. The concentration weighted average was found at 3.36-5.79

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
other information
Study period:
14-24 May, 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Justification for type of information:
LogPow could not be calculated by HPLC-UV due to the sample not giving a suitable peak in the chromatography. Thus, it is concluded that the used HPLC-UV method (OECD 117) is not applicable for this type of UVCB substance.
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
not specified
GLP compliance:
not specified
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Temp.:
20 °C
pH:
ca. 7
Remarks on result:
not determinable
Remarks:
Pow could not be calculated by HPLC-UV due to the sample not giving a suitable peak in the chromatography
Details on results:
Pow could not be calculated by HPLC-UV due to the sample not giving a suitable peak in the chromatography
Conclusions:
A test for LogPow according to OECD 117-HPLC has been carried out. However, logPow could not be determined by the HPLC-UV as the sample did not give a suitable peak in the chromatography.
Executive summary:

A test for LogPow according to OECD 117-HPLC has been carried out. However, logPow could not be determined by the HPLC-UV as the sample did not give a suitable peak in the chromatography.

Description of key information

A test for LogPow according to OECD 117 (HPLC) has been carried out. However, logPow could not be determined by the HPLC-UV method as the sample did not give any a suitable peak in the chromatography.

According to EpiSuite ( US EPA Epi Suite v4.0) calculations, the logPow was found to vary between 1.43 to 13.58 for all substances present in >1wt% in the UVCB-substance. The concentration weighted average was found at 3.36-5.79.

Key value for chemical safety assessment

Log Kow (Log Pow):
5.79
at the temperature of:
25 °C

Additional information