First-aid measures

Emergency measure - Inhalation: Negligible.

Emergency measure - Eyes: Wash with water (during 10 minutes). Seek medical advice.

Emergency measure - Skin: Wash with water.

Emergency measure - Ingestion: Wash the mouth. Drink 1-2 glasses of water.

Fire-fighting measures

Recommended extinguishing agent: Foam, carbon dioxide, sprayed water and extinguising

powders.

Product arising from burning: CO2 and CO.

Product determined by test: N

Accidental release measures

Emergency measures in case of spillage: Collect using absorbent materials for liquids (sand, turf,

sawdust). Transfer to a specialized recycling company.

Handling and storage

Handling: Avoid dust accumulation and use mask and goggles.

Storage: No special measures.

Packaging of the substance and or preparation: 25 kg bags

25 kg fiber drums

750 kg supersacks

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: none
Transport: No dangerous product according to RID/ADR, GGVS/GGVE, ADNR,
IMDG, ICAO-TI/IATA-DGR
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: It reacts with strong oxidisers. No decomposition danger if

used according to recommendations.

Chemical reaction with water: none

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: none

Industry - Possibility of neutralisation: none

Industry - Possibility of destruction: controlled discharge: none

Industry - Possibility of destruction - incineration: Special incineration.

Industry - Possibility of destruction - water purification: not water soluble

Industry - Possibility of destruction - other: none

Public at large - Possibility of recovery/recycling: not applicable

Public at large - Possibility of neutralisation: not applicable

Public at large - Possibility of destruction: controlled discharge: not applicable

Public at large - Possibility of destruction - incineration: not applicable

Public at large - Possibility of destruction - water purification: not applicable