Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove from further exposure. If unconsciousness occurs,
seek immediate medical assistance and call a physician. If
breathing has stopped, use mouth-to-mouth resuscitation. In
all cases, remove contaminated clothing immediately,
launder before reuse.
Emergency measure - Eyes: Flush thoroughly with water for at least 15 minutes. Seek
immediate medical attention; if medical assistance is not
immediately available, flush for an additional 15 minutes.
Emergency measure - Skin: Wash with soap and water. If widespread contact,
immediately remove contaminated clothing under a safety
shower and wash exposed areas with soap and large
quantities of water, seek medical attention.
Emergency measure - Ingestion: Do not induce vomiting. Give large quantites of milk or
water. Seek medical attention (call a physician
immediately). Do not induce vomiting or give anything by
mouth to an unconscious person.

Fire-fighting measures

Recommended extinguishing agent: Recommended extinguishing agents: Use water to keep
containers cool and water spray to disperse vapours and
protect workers attempting to seal leaks.

Product arising from burning: Products arising from pyrolysis: Combustion products may
contain carbon, nitrogen, sulphur and phosphorus oxides.

Protective equipment: Protective equipment: Wear a self-contained breathing
apparatus. Prevent run-off from entering streams or
drinking water supplies.

Accidental release measures

Emergency measures in case of spillage: Contain spill and absorb material on fire retardant-treated
sawdust, diatomaceous earth etc. Shovel up and dispose of
at an approved incineration facility. Remove leaking
containers to a separate area. Personnel must use
protective equipment.

Handling and storage

Handling: Avoid personal contact. Use in a well ventilated area.
Earth all transfer equipment and ensure area is bonded.
Wear chemical type goggles, a face shield and protective
clothing (impervious suits and boots for large quantities).

Storage: Store separately or outside. Ensure storage containers are
bonded and earthed. Drums must be fitted with self-closing
valves, pressure vacuum bungs and flame arrestors.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: Name: Flammable liquid, corrosive, NOS Class: Flammable
liquid, UN 2924
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Other dangers: Substance may react with strong oxidisers.

Chemical reaction with water: Chemical reaction with water: None reported.

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for reuse is not possible

Industry - Possibility of neutralisation: No known chemical method for neutralising the hazardous
effects.

Industry - Possibility of destruction: controlled discharge: Disposal at a controlled landfill site or by discharge to
water is not recommended.

Industry - Possibility of destruction - incineration: Recommended method of disposal in accordance with local
regulations. Either neat or as a solution in oil the
substance may be burned in an enclosed, controlled burner
for fuel value or disposal. Waste gas treatment should be
used to remove nitrogen, sulphur and phosphorus oxides.

Industry - Possibility of destruction - water purification: The substance has a low water solubility. Removal from
waste water (as an oil phase) using an oil/water separator
is recommended (this will not remove the toxic fraction).
Discharge to waste water is not recommended as the
substance may be inhibitory to microbial activity.
Treatment of the waste water using activated carbon after
separation to reduce contamination to a minimum should be
used.

Public at large - Possibility of recovery/recycling: Recovery from preparations by the public is not possible.

Public at large - Possibility of neutralisation: Not applicable at the concentrations present in
preparations.

Public at large - Possibility of destruction: controlled discharge: Not recommended

Public at large - Possibility of destruction - incineration: Preparations may be incinerated at an approved facility
fitted with waste gas treatment for nitrogen, sulphur and
phosphorus oxides.

Public at large - Possibility of destruction - water purification: Not recommended.

Public at large - Possibility of destruction - others: Dispose of preparations in oil recovery systems.