Administrative data

Endpoint:
density, other
Remarks:
Density of Liquids and Solids / OECD 109 / A.3.
Type of information:
experimental study
Adequacy of study:
key study
Study period:
July 2018
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
GLP compliance:
no
Remarks:
GLP compliance not required
Type of method:
pycnometer method

Test material

Constituent 1
Reference substance name:
Reaction mass of Cuprate(4-), [μ-[[3,3'-methylenebis[6-[[5-[(2,4-disulfophenyl)azo]-2,4-dihydroxyphenyl]azo]benzoato]](8-)]]di-, sodium and copper(2+) disodium 5-[(3-carboxyphenyl)methyl]-2-[2-{4-hydroxy-2-oxido-5-[2-(4-sulfophenyl)diazen-1-yl]phenyl}diazen-1-yl]benzoate” and sodium chloryde
EC Number:
948-009-7
Molecular formula:
Not applicable for a multi-constituent substance
IUPAC Name:
Reaction mass of Cuprate(4-), [μ-[[3,3'-methylenebis[6-[[5-[(2,4-disulfophenyl)azo]-2,4-dihydroxyphenyl]azo]benzoato]](8-)]]di-, sodium and copper(2+) disodium 5-[(3-carboxyphenyl)methyl]-2-[2-{4-hydroxy-2-oxido-5-[2-(4-sulfophenyl)diazen-1-yl]phenyl}diazen-1-yl]benzoate” and sodium chloryde
Test material form:
solid: particulate/powder
Details on test material:
Acid brown 161 batch no. ID151860 CAS no. 85338-16-5
Composition of the muti-constituent substance is included in the report as an extract of the analytical report.

Results and discussion

Density
Key result
Type:
relative density
Density:
ca. 2.009 g/cm³
Temp.:
20 °C

Any other information on results incl. tables

1. Measured values:

All measured values are given in the following table:

First Determination

 

 

 

.

.

Weighing #

m1

m2

m3

m4

m5

Substance

Pycn. empty

Pycn.+ H2O

Pycn.+repl. liq..

Pycn. + test substance

Pycn+test substance+repl. liq..

Mass in g

36.7439

61.6088

56.2536

44.8712

61.2165

Temperature in °C

20.2

20.2

20.2

20.0

20.2

Second Determination

 

 

 

 

.

Weighing #

m1

m2

m3

m4

m5

Substance

Pycn. empty

Pycn.+ H2O

Pycn.+repl. liq..

Pycn. + test substance

Pycn+test substance+repl. liq..

Mass in g

36.7443

61.6079

56.2630

42.3526

59.6812

Temperature in °C

19.8

20.0

20.0

20.2

20.0

2. Calculated Values:

Calculation of results: For equations used in the calculations, please refer to pages 7 and 8 of the report.

The following values were calculated.

First Determination

 

 

Error rel.

Error abs.

Temperature

20.2

 °C

 

0.1

Density of water

0.998203

g/cm3

2.00%

0.0002

Volume of Pycnometer

24.9097

cm3

 

 

Density of Replacement Liquid

0.7832

 

 

 

Density of Test Substance

2.0116

g/cm3

0.0508%

0.0010

Second Determination

 

 

Error rel.

Error abs.

Temperature

20.0

 °C

 

0.1

Density of water

0.998203

g/cm3

2.00%

0.0002

Volume of Pycnometer

24.9084

cm3

 

 

Density of Replacement Liquid

0.7836

 

 

 

Density of Test Substance

2.0067

g/cm3

0.0710%

0.0014

3. Presentation of Results

Results of the single determinations with the respective error as well as the mean value and its standard deviation are presented in the following tables:

  Results of Single Determinations

Determination

Density in g/cm3

Error of Determ. in g/cm3

1

2.0116

0.0010

2

2.0067

0.0014

Results – Mean Values

Parameter

Value

Unit

Standard Deviation

Relative Standard Deviation

Volume of Pycnometer

24.91

cm3

0.0009

0.00%

Density of Test Substance

2.0091

g/cm3

0.0035

0.17%

Density of Test Substance

2009.1

kg/m3

3.5

0.17%

Relative Density of Test Substance

2.0091

 

0.0035

0.17%

Applicant's summary and conclusion

Conclusions:
Using the pycnometer method, a density of

2.0091± 0.0014 g/cm3 at 20 ± 0.2 °C

was measured. This value is the mean of two independent determinations with the maximum error of a single determination.

Standard deviation was 0.0035 g/cm3, showing good correlation of the two determinations.