Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 May 2005
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: PDC Lot 1, Pail 2
- Expiration date of the lot/batch: 23 Mar 2006
- Purity: 99.959%
- Synonyms: MTDID 665
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: room temperature in the dark
Key result
Atm. press.:
102.1 kPa
Remarks on result:
no flash point - measurement carried out until boiling temperature
Remarks:
sample boiled at 97 °C

Boiling was confirmed visually.

Interpretation of results:
GHS criteria not met
Conclusions:
HFE s-601 has no flash point below its boiling temperature or 97 °C by Pensky-Martens closed cup test (EU method A.9).
Executive summary:

No flash-point could be determined using the Pensky-Martens closed cup method. No flammable vapour/air mixture was produced in the test vessel at temperatures below boiling, which was observed visually at 97 °C, 102.1 kPa. The study was conducted in accordance with EU method A.9 and was GLP compliant; therefore the study is considered reliable without restrictions and is suitable for Classification & Labeling and Risk Assessment.

Description of key information

HFE s-601 has no flash point below its boiling temperature or 97 °C by Pensky-Martens closed cup test (EU method A.9).

Key value for chemical safety assessment

Additional information

No flash-point could be determined using the Pensky-Martens closed cup method. No flammable vapour/air mixture was produced in the test vessel at temperatures below boiling, which was observed visually at 97 °C, 102.1 kPa. The study was conducted in accordance with EU method A.9 and was GLP compliant; therefore the study is considered reliable without restrictions and is suitable for Classification & Labeling and Risk Assessment.