Registration Dossier

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Qualifier:
according to
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
GLP compliance:
yes (incl. certificate)
Type of method:
differential scanning calorimetry
Key result
Melting / freezing pt.:
<= -90 °C
Atm. press.:
>= 1 002 - <= 1 007 hPa
Remarks on result:
other: The substance is a liquid at -90°C
Conclusions:
The test item SENSATIS® PC134 PURE has no melting point at atmospheric pressure (1002 hPa(a) - 1007 hPa(a)) from -90 °C up to the exothermic effect starting at approx. 220 °C as determined by differential scanning calorimetry according to Regulation EC No. 440/2008 Method A.1. and OECD Test Guideline 102 (1995). Therefore, the melting point is considered to be ≤ -90 °C.

Description of key information

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
-90 °C

Additional information