Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 115 (Surface Tension of Aqueous Solutions)
Qualifier:
according to guideline
Guideline:
EU Method A.5 (Surface Tension)
GLP compliance:
yes (incl. QA statement)
Type of method:
ring method

Test material

Constituent 1
Chemical structure
Reference substance name:
3,3'-oxydipropanol
EC Number:
219-251-4
EC Name:
3,3'-oxydipropanol
Cas Number:
2396-61-4
Molecular formula:
C6H14O3
IUPAC Name:
3-(3-hydroxypropoxy)propan-1-ol
Test material form:
liquid

Results and discussion

Surface tension
Key result
Surface tension:
70.9 mN/m
Temp.:
20 °C
Conc.:
1 056 mg/L

Applicant's summary and conclusion

Conclusions:
According to OECD Test Guideline 115 and Regulation EC No. 440/2008 Part A Method A.5. the surface tension at 20 °C of test item SENSATIS® PC134 PURE was determined to be
70.9 mN/m. According to Regulation EC No. 440/2008 Part A Method A.5. the test item is not regarded as surface active material.