Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
acute toxicity: inhalation
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
July, 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: ASTM D6377
Deviations:
no
GLP compliance:
no
Type of method:
other: expansion method
Remarks:
Instrument: MINIVAP VPXpert by GRABNER INSTRUMENTS
Key result
Test no.:
#1
Temp.:
25 °C
Vapour pressure:
2.3 kPa
Test no.:
#1
Temp.:
30 °C
Vapour pressure:
3.6 kPa
Test no.:
#1
Temp.:
35 °C
Vapour pressure:
4.3 kPa
Test no.:
#1
Temp.:
40 °C
Vapour pressure:
5.2 kPa
Test no.:
#1
Temp.:
45 °C
Vapour pressure:
6.1 kPa
Test no.:
#1
Temp.:
50 °C
Vapour pressure:
7.2 kPa
Test no.:
#1
Temp.:
55 °C
Vapour pressure:
8.7 kPa
Test no.:
#1
Temp.:
60 °C
Vapour pressure:
10.5 kPa
Test no.:
#1
Temp.:
65 °C
Vapour pressure:
12.3 kPa
Test no.:
#1
Temp.:
70 °C
Vapour pressure:
14.2 kPa
Test no.:
#1
Temp.:
75 °C
Vapour pressure:
16.7 kPa
Test no.:
#1
Temp.:
80 °C
Vapour pressure:
19.7 kPa
Conclusions:
The substance has a vapour pressure of 2.3 kPa at 25°C.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion