Registration Dossier

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
9 November 2017 to ****
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
GLP compliance:
yes
Type of method:
differential scanning calorimetry
Specific details on test material used for the study:
Purity: >99% (UVCB)
Storage conditions: Room temperature in the dark
Key result
Melting / freezing pt.:
-20 °C
Remarks on result:
other: no evidence of freeze/melt point
Conclusions:
The melting point is reported as <-20°C, because there was no evidence of a freeze/melt point present at the -20°C initial temperature.
Executive summary:

The melting point is reported as <-20°C, because there was no evidence of a freeze/melt point present at the -20°C initial temperature

Description of key information

The melting point is reported as <-20°C, because there was no evidence of a freeze/melt point present at the -20°C  initial temperature.

Key value for chemical safety assessment

Additional information