Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
9 November 2017 to ****
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Specific details on test material used for the study:
Purity: >99% (UVCB)
Storage conditions: Room temperature in the dark
Key result
Flash point:
193 °C
Atm. press.:
763.113 mm Hg
Interpretation of results:
GHS criteria not met
Conclusions:
Flash point is 193°C at barometric pressure of 763.113 mmHg
Executive summary:

The test material according to EC No. 440/2008 A.9 was determined to have a flash point of 193°C (Not classified as a flammable liquid).

Description of key information

Flash point is 193°C at barometric pressure of 763.113 mmHg.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
193 °C

Additional information