Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ASTM D 6450-12e1 Standard Test Method for Flash Point by Continuously Closed Cup (CCCFP) Tester
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point apparatus:
other: Low Temperature Closed-cup Flash Point Tester: MINIFLASH FLPL

Test material

Constituent 1
Chemical structure
Reference substance name:
1,3-difluorobenzene
EC Number:
206-746-5
EC Name:
1,3-difluorobenzene
Cas Number:
372-18-9
Molecular formula:
C6H4F2
IUPAC Name:
1,3-difluorobenzene

Results and discussion

Flash point
Flash point:
-8 °C
Atm. press.:
1 atm

Applicant's summary and conclusion

Conclusions:
-8.0°C