Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: ASTM D97 (Standard Test Method for Pour Point of Petroleum Products)
GLP compliance:
no
Type of method:
pour point

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Melting / freezing point
Melting / freezing pt.:
57 °C
Atm. press.:
ca. 1 013 hPa
Remarks on result:
other:
Remarks:
Pour point

Any other information on results incl. tables

There are no values given for pressure. Pour point assumed to be measured at normal pressure (ca. 1013 hPa).

Applicant's summary and conclusion