Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-06-04 to 2018-09-03
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Test procedure:
burning rate test: preliminary screening test
Burning time:
559 s
Remarks on result:
other: The test item propagated burning along 190 mm of the powder train in 559 seconds. Further tests to measure the rate of burning were not necessary.

The test item propagated burning along 190 mm of the powder train in 559 seconds. Further tests to measure the rate of burning were not necessary.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item propagated burning along 190 mm of the powder train in 559 seconds. Therefore, the test item is classified as a not readily combustible solid when tested according to UN-MTC Procedure N.1.
Executive summary:

The test item propagated burning along 190 mm of the powder train in 559 seconds. Therefore, the test item is classified as a not readily combustible solid when tested according to UN-MTC Procedure N.1.

Description of key information

The test item is classified as a not readily combustible solid.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The test propagated burning along 190 mm of the powder train in 559 seconds. Therefore, the test item is classified as a not readily combustible solid when tested according to UN-MTC Procedure N.1.