Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
hydrolysis
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study has been presented to ECHA in the framework of a NONS notification. The document is now public because presented more than 12 years ago.

Data source

Reference
Reference Type:
other: body responsible for the test
Title:
Unnamed
Year:
1987

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: 84/449/EWG, C.10 (Hydrolyse)
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
401-310-2
EC Name:
-
Cas Number:
93912-64-2
Molecular formula:
Hill formula: C37H23N10O22S7Cl.6Na CAS formula: C37H23N10O22S7ClNa6
IUPAC Name:
Hexasodium 2-[8-amino-7-[[5-[[4-chloro-6-[[3-[[2-(sulfato)ethyl]sulfonyl]phenyl]amino]-1,3,5-triazin-2-yl] amino]-2 sulfonatophenyl]azo]-1-hydroxy-3,6-disulfonato-2-naphthalenyl]azo]-naphthalene-1,5-disulfonate

Results and discussion

Transformation products:
not specified
Dissipation DT50 of parent compoundopen allclose all
pH:
4
Temp.:
50 °C
DT50:
> 8 760 h
pH:
7
Temp.:
50 °C
Hydrolysis rate constant:
0 s-1
DT50:
ca. 5.9 h
pH:
7
Temp.:
40 °C
Hydrolysis rate constant:
0 s-1
DT50:
ca. 23.9 h
pH:
9
Temp.:
50 °C
DT50:
< 2.4 h
Details on results:
A half-life of approx. 13 days was determined under environmentally relevant conditions (pH: 7, T: 25 degrees C). It is not assumed that this influenced the result of the water toxicity test. The report concludes that a pseudo reaction of the first order is involved here.
Method: a HPLC analysis with methanol/water as a mobile phase and UV detection was performed.

Applicant's summary and conclusion