Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-10-17
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
GHS criteria not met
Conclusions:
According to the definition in the Council Regulation (EC) No 440/2008 that is pursuant to Regulation (EC) No 1907/2006 Octadecanoic acid, reaction products with acetic acid and tetraethylenepentamine has not to be considered as flammable.
Executive summary:

The test item was formed into a particle train. A hot flame from a gas burner with a diameter of about 6 mm is used to ignite the pile at one end. In the preliminary screening test, the substance melts and partly decomposes. After removal of the gas burner the flame does not propagate along the test train.

According to the definition in the Council Regulation (EC) No 440/2008 that is pursuant to Regulation (EC) No 1907/2006 Octadecanoic acid, reaction products with acetic acid and tetraethylenepentamine has not to be considered as flammable.

Description of key information

According to the definition in the Council Regulation (EC) No 440/2008 that is pursuant to Regulation (EC) No 1907/2006 Octadecanoic acid, reaction products with acetic acid and tetraethylenepentamine has not to be considered as flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The test item was formed into a particle train. A hot flame from a gas burner with a diameter of about 6 mm is used to ignite the pile at one end. In the preliminary screening test, the substance melts and partly decomposes. After removal of the gas burner the flame does not propagate along the test train.

According to the definition in the Council Regulation (EC) No 440/2008 that is pursuant to Regulation (EC) No 1907/2006 Octadecanoic acid, reaction products with acetic acid and tetraethylenepentamine has not to be considered as flammable.

Justification for classification or non-classification