Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 446-240-3 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Flammability
Administrative data
Link to relevant study record(s)
- Endpoint:
- flammable solids
- Data waiving:
- study technically not feasible
- Justification for data waiving:
- the study does not need to be conducted because the substance is a liquid
- other:
- Justification for type of information:
- JUSTIFICATION FOR DATA WAIVING
In accordance with section 1.2 of REACH Regulation (EC) No. 1907/2006 Annex XI the study of flammability does not need to be completed based on weight of available evidence. The substance has an experimentally determined flashpoint > 60 °C and therefore under CLP Regulation (EC) 1272/2008 cannot be considered a “flammable liquid”. Therefore testing for flammability is scientifically unjustified.
For liquids the primary value for ease of ignition is the flash point conducted using Method A9 ‘Flash Point Method’ of Council Regulation (EC) No 440/2008. The result of the Flash Point test is used to allocate a liquid substance into the appropriate flammability class. Other measures of flammability include pyrophoricity and flammability on contact with water. These can be considered not a concern for the substance and testing waived if consideration of the structure and experience in handling and use show that no effects are envisaged. Such a screening procedure represents an intelligent testing strategy for flammability. If applied correctly then only liquid substances for which it is suspected will give a positive result in either the pyrophoric properties or flammability on contact with water tests need to be tested.
A review of the structure suggests that there are no chemical groups present that would imply pyrophoric properties or flammability on contact with water. A review of handling and use implies no pyrophoric properties or flammability on contact with water. Based on the absence of structural alerts and experience in handling and use negative results are predicted for pyrophoric properties and flammability of contact with water. Based on the known Flash Point of the substance it is considered not to be flammable.
References:
1. UN Transport of Dangerous Goods Manual of Tests and Criteria, Sixth Edition (2015)
2. Bretherick (1999) Bretherick’s Handbook of Chemical Reactive Hazards: An Indexed Guide to Published Data, 6th Edition (2 volume set)
3. ECHA Guidance on Information Requirements and Chemical Safety Assessment (Chapter R.7a: Endpoint Specific Guidance, R.7.1.10.2, version 6.0, July 2017)
4. REACH Regulation (EC) 1907/2006, Annex XI, section 1
5. CLP Regulation (EC) 1272/2008, Annex I, section 2.6.1
6. ECHA Guidance on Application on the CLP Criteria, section 2.6 (version 5.0, July 2017) - Endpoint:
- substances / mixtures which in contact with water emit flammable gases
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- the study does not need to be conducted because the organic substance does not contain metals or metalloids and hence, the classification procedure does not need to be applied
- other:
- Justification for type of information:
- JUSTIFICATION FOR DATA WAIVING
In accordance with section 1 of REACH Regulation (EC) No. 1907/2006 Annex XI, the does not need to be performed as based on assessment of the chemical structure flammability on contact with water properties are not to be expected and this is supported by experience in handling and use for the substance. According to ECHA Guidance on Information Requirements and Chemical Safety Assessment (Chapter R.7a: Endpoint Specific Guidance, R.7.1.10.8, July 2017), flammability on contact with water testing is scientifically unjustified. - Endpoint:
- pyrophoric liquids
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
- other:
- Justification for type of information:
- JUSTIFICATION FOR DATA WAIVING
In accordance with section 1 of REACH Regulation (EC) No. 1907/2006 Annex XI, the study does not need to be performed as based on assessment of the chemical structure pyrophoric properties are not to be expected and this is supported by experience in handling and use for the substance. According to ECHA Guidance on Information Requirements and Chemical Safety Assessment (Chapter R.7a: Endpoint Specific Guidance, R.7.1.10.5, July 2017), pyrophoricity testing is scientifically unjustified.
Referenceopen allclose all
Description of key information
Flammability: non-flammable liquid ; experimentally determined flash-point > 60 °C at 101.325 kPa.
Key value for chemical safety assessment
- Flammability:
- non flammable
Additional information
In accordance with section 1.2 of REACH Regulation (EC) No. 1907/2006 Annex XI the study of flammability does not need to be completed based on weight of available evidence. The substance has an experimentally determined flashpoint > 60 °C and therefore under CLP Regulation (EC) 1272/2008 cannot be considered a “flammable liquid”. Therefore testing for flammability is scientifically unjustified.
For liquids the primary value for ease of ignition is the flash point conducted using Method A9 ‘Flash Point Method’ of Council Regulation (EC) No 440/2008. The result of the Flash Point test is used to allocate a liquid substance into the appropriate flammability class. Other measures of flammability include pyrophoricity and flammability on contact with water. These can be considered not a concern for the substance and testing waived if consideration of the structure and experience in handling and use show that no effects are envisaged. Such a screening procedure represents an intelligent testing strategy for flammability. If applied correctly then only liquid substances for which it is suspected will give a positive result in either the pyrophoric properties or flammability on contact with water tests need to be tested.
A review of the structure suggests that there are no chemical groups present that would imply pyrophoric properties or flammability on contact with water. A review of handling and use implies no pyrophoric properties or flammability on contact with water. Based on the absence of structural alerts and experience in handling and use negative results are predicted for pyrophoric properties and flammability of contact with water. Based on the known Flash Point of the substance it is considered not to be flammable.
References:
1. UN Transport of Dangerous Goods Manual of Tests and Criteria, Sixth Edition (2015)
2. Bretherick (1999) Bretherick’s Handbook of Chemical Reactive Hazards: An Indexed Guide to Published Data, 6th Edition (2 volume set)
3. ECHA Guidance on Information Requirements and Chemical Safety Assessment (Chapter R.7a: Endpoint Specific Guidance, R.7.1.10.2, version 6.0, July 2017)
4. REACH Regulation (EC) 1907/2006, Annex XI, section 1
5. CLP Regulation (EC) 1272/2008, Annex I, section 2.6.1
6. ECHA Guidance on Application on the CLP Criteria, section 2.6 (version 5.0, July 2017)
Justification for classification or non-classification
The substance does not meet classification criteria under Regulation (EC) No 1272/2008 for flammability.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.