Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
06 September 2018 - 14 September 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. certificate)
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

The pile charred and ignited with a yellow tipped blue flame which self-extinguished 22 seconds after the Bunsen flame was removed without propagating combustion.

The result of the preliminary screening test obviated the need to perform the main test.

Conclusions:
The test item has been determined to be not highly flammable as it failed to support combustion in the preliminary screening test.
Executive summary:

The test item was determined to be not highly flammable, using a procedure designed to be compatible with Method A.10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Description of key information

The test item was determined to be not highly flammable, using a procedure designed to be compatible with Method A.10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification