Administrative data

Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: United Nations Recommendations on the Transport of Dangerous Goods Manual of Tests and Criteria - Sixth revised edition (2015) (EC) No. 1272/2008 (CLP)
Version / remarks:
Series 1 type (b) Test 1 (b) (Part I, section 11.5.1) for KOENEN test
Series 3 type (a) Test 3 (a) (ii) (Part I, section 13.4.2) for BAM FALLHAMMER
Series 3 type (b) Test 3 (b) (i) (Part I, section 13.5.1) for BAM FRICTION apparatus
Principles of method if other than guideline:
Series 1 type (b) Test 1 (b) (Part I, section 11.5.1) for KOENEN test
Series 3 type (a) Test 3 (a) (ii) (Part I, section 13.4.2) for BAM FALLHAMMER
Series 3 type (b) Test 3 (b) (i) (Part I, section 13.5.1) for BAM FRICTION apparatus
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
2-amino-5-chlorobenzophenone
EC Number:
211-949-7
EC Name:
2-amino-5-chlorobenzophenone
Cas Number:
719-59-5
Molecular formula:
C13H10ClNO
IUPAC Name:
(2-amino-5-chlorophenyl)(phenyl)methanone
Test material form:
solid: particulate/powder

Results and discussion

Small-scale preliminary testsopen allclose all
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
not thermal sensitive if heated under defined confinement
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
negative (not further specified)
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
negative (not further specified)

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The explosiveness is determined according to United Nations Recommendations on the Transport of Dangerous Goods Manual of Tests and Criteria - Sixth revised edition (2015) (EC) No. 1272/2008 (CLP).
The study reports negative results.
The test item was not considered to have explosive properties in the experimental conditions used. According to EC N° 1272/2008 (CLP), the test item was not classified.
Executive summary:

The explosiveness is determined according to United Nations Recommendations on the Transport of Dangerous Goods Manual of Tests and Criteria - Sixth revised edition (2015) (EC) No. 1272/2008 (CLP).

The study reports negative results.

The test item was not considered to have explosive properties in the experimental conditions used. According to EC N° 1272/2008 (CLP), the test item was not classified.