Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Justification for type of information:
A flash point is provided as the substance is a low melting substance. No study report is available. Information on test material, test guideline and result was taken from a product description sheet. No details are available.
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
EN 22719
Deviations:
not specified
GLP compliance:
no
Type of method:
non-equilibrium method
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
5474 mPas (calculated value)
Specific details on test material used for the study:
Melting temperature of the substance: 66.9°C.
Key result
Flash point:
193 °C
Atm. press.:
1 013 hPa
Interpretation of results:
GHS criteria not met
Conclusions:
Flash point: 193°C (Pensky Martens closed cup)

Description of key information

The flash point of the substance is 193°C (Pensky Martens closed cup).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
193 °C

Additional information