Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 618-312-6 | CAS number: 898566-17-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Adsorption / desorption
Administrative data
Link to relevant study record(s)
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2015-09-27 to 2015-09-27
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- Deviations:
- no
- Guideline:
- EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: European Commission (EC), Technical Guidance Document on Risk Assessment Part III, Chapter 4.3: “Use of (Quantitative) Structure Activity Relationships ((Q)SARs) - Soil and Sediment Sorption”, 2003.
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- See study report
- Type of method:
- HPLC estimation method
- Media:
- other: HPLC column
- Specific details on test material used for the study:
- - Source and lot/batch No.of test material: M14KB4863
- Expiration date of the lot/batch:10 November 2017
- Purity:100.5% (based on HPLC assay)
- Storage condition of test material:At room temperature - Radiolabelling:
- no
- Test temperature:
- 35°C +/- 1°C
- Details on study design: HPLC method:
- - Analytical conditions
Instrument: Acquity UPLC system (Waters, Milford, MA, USA)
Detector: Acquity UPLC TUV detector (Waters)
Column: Acquity UPLC HSS Cyano, 100 mm x 2.1 mm i.d., dp = 1.8 µm (Waters)
Column temperature: 35°C +/- 1°C
Mobile phase A: 55/45 (v/v) methanol/water B: methanol
-A gradient was applied in order to elute components with log Koc > 5.63 from the column. The reference compound was eluted in the isocratic part of the method.
time in minutes = 0 %A = 100 %B = 0
time in minutes = 8 %A = 100 %B = 0
time in minutes = 10 %A = 0 %B = 100
time in minutes = 13 %A = 0 %B = 100
time in minutes = 13.1 %A = 100 %B = 0
time in minutes = 16 %A = 100 %B = 0
Flow: 0.4 ml/min
Injection volume: 5 µl
UV detection: 210 nm
-Reference substance solutions:A stock solution of the reference substance at a concentrations of approximately 1 g/l in methanol was used. The stock solution was diluted by a factor of 100 with 55/45 (v/v) methanol/water. The blank solution for the reference substance was 55/45 (v/v) methanol/water.
-Reference substances: 4,4’-DDT
-Test solution
A 2000 mg/l stock solution of the test item was prepared in methanol. In order to dissolve the test item the stock solution was ultrasonicated for 25 minutes. The stock solution was diluted by a factor of 200 with 55/45 (v/v) methanol/water. The final concentration of the test item solution was 10.0 mg/l. The test item blank solution was 55/45 (v/v) methanol/water
-Injections
The reference substance and test item solutions were injected in duplicate. Blank solutions were analysed by single injection.
- Calculation of capacity factors k': from retention time of reference items, the test item, and then on-sorbed chemical item
- Determination of the log Koc value: a correlation of log k' versus log Koc of the reference items is plotted using linear regression - the log k' value of the test item is then used to calculate its log Koc value
- Analytical monitoring:
- no
- Key result
- Type:
- Koc
- Value:
- > 430 000 dimensionless
- pH:
- 7
- Key result
- Type:
- log Koc
- Value:
- > 5.63 dimensionless
- pH:
- 7
- Details on results (HPLC method):
- In the chromatogram of the test item solution, one peak with a retention time of 10.2 minutes was observed.
Under the same analytical conditions, the retention time of 4,4’-DDT (log Koc = 5.63) was 7.23 minutes. - Validity criteria fulfilled:
- yes
- Conclusions:
- The HPLC method using soil-adsorption-reference data was applied for the determination of the adsorption coefficient (Koc) of JNJ-39453193-AAA (T003063).
The Koc and log Koc values of the test item at neutral pH were >430000 and >5.63 respectively.
Reference
No pKa values for acidic and basic groups in the molecular structure of the test item were calculated.
Description of key information
This endpoint is covered with a GLP-study (Brekelmans, 2016) performed according to standard test guideline OECD 121. The mean log Koc of T003063 was determined to be 5.63 using the HPLC estimation method. The partition coefficients in soil, sediment, suspended matter and raw sewage sludge were calculated from the Koc value and the fraction of organic carbon in the compartment as stipulated in the ECHA guidance Chapter 16 - Table R.16-11.
Key value for chemical safety assessment
- Koc at 20 °C:
- 430 000
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.