Registration Dossier

Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
water solubility
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
weight of evidence
Study period:
2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
accepted calculation method
Justification for type of information:
Due to the structural similarity it can be concluded that the water solubility of EDTA-CoH2 will not be significantly different.
Reason / purpose:
read-across source
Principles of method if other than guideline:
The water solubility was calculated by EPI Suite program (WSKOW v.1.41).
Key result
Water solubility:
>= 1 000 mg/L
Conc. based on:
test mat.
Temp.:
25 °C
pH:
7
Details on results:
Calculated by EPI (estimation program interface) Suite program with the model WSKOW v.1.41 (for estimating water solubility).
Conclusions:
The water solubility for EDTA-CoNa2 was calculated as >1000 mg/L by EPI Suite program (WSKOW v.1.41).
Based on the structural similarity the solubility of ETDA-CoH2 will be similar.

Description of key information

The water solubility for EDTA-CoNa2 was calculated as >1000 mg/L by EPI Suite program (WSKOW v.1.41).

Based on the structural similarity the solubility of ETDA-CoH2 will be similar.

Key value for chemical safety assessment

Water solubility:
1 g/L
at the temperature of:
25 °C

Additional information