Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 20, 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no
Specific details on test material used for the study:
Purity: of test item ≥98%
Impurity: Barbituric acid ≤0.3%
Supplier: Novozymes A/S
Lot number: 201713807
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
120 s
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
not classified based on GHS criteria
Conclusions:
Violuric acid is not considered a flammable solid according to test method EU A.10. FLAMMABILITY (SOLIDS)
Executive summary:

Violuric acid is not considered flammable solid according to test method EU A.10. FLAMMABILITY (SOLIDS)

Description of key information

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

Violuric acid is not considered highly flammable according to test method EU A.10. FLAMMABILITY (SOLIDS)