Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Remarks:
solid
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 20, 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
no
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Atm. press.:
1 013 hPa
Remarks on result:
no flash point according to standard method
Remarks:
No flash point dertermined up to 100°C. Heating continued up to 250°C with no flash point determined.
Interpretation of results:
other: No flash point obtained
Conclusions:
No flash point was obtained for solid/crystaline violuric acid using test method ISO 3679:2015
Executive summary:

Solid/crystaline violuric acid was tested in accordance to test method ISO 3679:2015 (EC Method A.9). No flash point was determined.

Description of key information

Solid/crystaline violuric acid was tested in accordance to test method ISO 3679:2015 (EC Method A.9). No flash point was determined.

Key value for chemical safety assessment

Additional information

No flash point was obtained for solid/crystaline violuric acid using test method ISO 3679:2015