Registration Dossier

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
other: CIPAC MT 3.2
Qualifier:
according to
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Qualifier:
according to
Guideline:
EU Method A.3 (Relative Density)
GLP compliance:
yes
Type of method:
pycnometer method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid: viscous
Specific details on test material used for the study:
Batch number: 78-242-15
Dynamic viscosity of test material:
Dynamic viscosity of the test item (extrapolated at 20°C): 3.59 x 10E8 cSt

Results and discussion

Densityopen allclose all
Type:
relative density
Density:
0.743 other: dimensionless
Temp.:
20 °C
Type:
density
Density:
0.743 g/cm³
Temp.:
20 °C

Any other information on results incl. tables

Determination

W1

(g)

W2

(g)

W3

(g)

W4

(g)

W5

(g)

Density

(g/mL)

A

36.4013

86.2862

36.4013

38.3085

85.6276

0.7420

B

31.3332

79.7894

31.3332

33.3704

79.0895

0.7430

Mean value :

0.7425

Delta % :

0.13%

Specific gravity (pure number) :

0.7438

Relative density (pure number) :

0.7425

Applicant's summary and conclusion

Conclusions:
The density of the substance is 0.7425 g/ml at 20°C.