Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 103 (Boiling Point)
Qualifier:
according to
Guideline:
EU Method A.2 (Boiling Temperature)
GLP compliance:
yes
Type of method:
differential scanning calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid: viscous
Specific details on test material used for the study:
Batch number: 78-242-15

Results and discussion

Boiling point
Remarks on result:
other: 400 - 470°C Exothermic reaction showing a probable degradation of the test item at 432.0°C

Applicant's summary and conclusion

Conclusions:
The substance degrades before boiling (probable degradation at 432°C).