Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02 May 2018 to 25 May 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method
Type:
relative density
Density:
1.12 other: unitless
Temp.:
20 °C

Table 1:Results of relative density study

 Parameter  Replicate 1  Replicate 2
 w1 24.82253 

 24.60289

 w2

 49.40038

 49.68541

 w3

 44.75251

44.93729 

 w4

 27.87885

27.59806 

 w5

 45.59723

45.77335 

 W1

 24.57785

25.08252 

 W2

 19.92998

20.33440 

 W3

 3.05632

2.99517 

 W4

 17.71838

18.17529 

 W5

2.21160

2.15911

 

 

 

 ptl

 0.8093

0.8091 

 Mean ptl

0.8092

 Vs

2.733

2.668 

 Dt4

 1.12

1.12 

 Mean Dt4

 1.12

Where:

w1= weight of empty pycnometer (g)

w2= weight of pycnometer and water (g)

w3= weight of pycnometer and displacement liquid (g)

w4= weight of pycnometer and test item (g)

w5= weight of pycnometer, test item and displacement liquid (g)

W1=Mass of water to fill pycnometer

W2= Mass of displacement liquid to fill pycnometer

W3= Mass of test item added to pycnometer

W4= Mass of displacement liquid required to fill pycnometer containing W3g of test item

W5= Mass of displacement liquid equivalent to W3g of test item

ptl= density of displacement liquid at temperature of determination (g/mL)

Dt4= relative density of test item at test temperature compared to water at 4°C

Conclusions:
The relative density of the test item was determined to be 1.12 at 20 °C.
Executive summary:

The relative density of the test item was determined in a study following OECD 109 and EC Method A.3 guidelines, using the pycnometer method. The relative density of the test item was determined to be 1.12 at 20 °C.

The study is a GLP compliant, guideline experimental study and is fully acceptable for assessment of this endpoint.

Description of key information

The relative density of the test item was determined to be 1.12 at 20 °C.

Key value for chemical safety assessment

Relative density at 20C:
1.12

Additional information

The relative density of the test item was determined in a study following OECD 109 and EC Method A.3 guidelines, using the pycnometer method.

The study is a GLP compliant, guideline experimental study and is fully acceptable for assessment of this endpoint.