Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 17 November 2017 to 19 November 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM E659 (Standard test method for autoignition temperature of liquid chemicals)
Deviations:
no
GLP compliance:
no
Key result
Auto-ignition temperature:
287 °C
Atm. press.:
1 016 hPa

Sample Designation

Trans-hex-2-en-1-ol

 Autoignition temperature/°C

287

Volume injected/cm3

0.30

Ignition delay time/s

40.4

Observed exotherms

94 K at 285oC with injected quantity 0.50 cm3

Cool flames?

None observed

Barometric pressure/ hPa

1028

Date of test

17-19November, 2017

Conclusions:
An auto-ignition temperature (liquids) of 287ºC was determined for the test item at 1,016 hPa.
Executive summary:

The auto-ignition temperature for Trans-hex-2-en-1-ol was determined according to the ASTM E659 Standard Test Method for Autoignition Temperature of Liquid Chemicals. The final auto-ignition temperature was reported as 287 ºC at 1,016 hPa.

Description of key information

The auto-ignition temperature for Trans-hex-2-en-1-ol was determined according to the ASTM E659 Standard Test Method for Autoignition Temperature of Liquid Chemicals. The final auto-ignition temperature was reported as 287 ºC at 1,016 hPa.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
287 °C

Additional information