Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 27, 2014-April 29, 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study performed according to recognized international guidelines and GLP. No deviation from the Guideline was observed.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report date:
2014

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
4,5-dihydro-2-undecyl-1H-imidazole-1-ethanol
EC Number:
205-271-0
EC Name:
4,5-dihydro-2-undecyl-1H-imidazole-1-ethanol
Cas Number:
136-99-2
Molecular formula:
C16H32N2O
IUPAC Name:
4,5-dihydro-2-undecyl-1H-imidazole-1-ethanol
Test material form:
other: solid
Details on test material:
-

Results and discussion

Flammable solids
Key result
Test procedure:
other: Study performed according to recognized international guidelines and GLP. No deviation from the Guideline was observed.
Remarks on result:
other: A quantitative result could not be determined because the substance does not burn under normal conditions, therefore the burning time could not be determined for non flammable compounds

Any other information on results incl. tables

The test substance could not be Ignited in the preliminary test. Therefore nu further testing of the burning rate was required and the substance (test item) is considered not to be flammable.

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
THhe test material is non flammable
Executive summary:

The determintaion of the flammability of the solid test item was performed according to EU A. 10 Method and GLP. No deviation from the guidelines was observed in the study. The test item did not ignite in the preliminary test, so it is considered as non flammable.