Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 17, 2016 - February 07, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
no
Remarks:
The test laboratory is GLP-certified.
Type of method:
dynamic method
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
0.41 Pa
Key result
Test no.:
#1
Temp.:
25 °C
Vapour pressure:
0.62 Pa
Key result
Test no.:
#1
Temp.:
50 °C
Vapour pressure:
3.96 Pa
Conclusions:
The vapour pressure of the test item GDMA was calculated by extrapolation of the measured vapour pressure curve for the temperatures 20, 25 and 50 °C, according to Regulation EC No. 440/2008 Method A.4. Vapour Pressure and OECD Test Guideline 104 (2006):
Temperature / °C Vapour pressure / Pa
20 0.41
25 0.62
50 3.96


Executive summary:

The vapour pressure of the test item GDMA was calculated by extrapolation of the measured vapour pressure curve for the temperatures 20, 25 and 50 °C, according to Regulation EC No. 440/2008 Method A.4. Vapour Pressureand OECD Test Guideline 104 (2006):

Temperature / °C

Vapour pressure / Pa

20

0.41

25

0.62

50

3.96

 

 

Description of key information

Key value for chemical safety assessment

Vapour pressure:
0.62 Pa
at the temperature of:
25 °C

Additional information