Registration Dossier

Physical & Chemical properties

Stability: thermal, sunlight, metals

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
thermal stability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 18, 2016 - February 13, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
Deviations:
no
GLP compliance:
no
Remarks:
The test laboratory is GLP-certified.
Specific details on test material used for the study:
Test Item: Thiolactic Acid 98/99%
Batch No.: 0000056625
Test substance thermally stable:
yes
Remarks:
up to 210°C

see report CSL-16 -2308.01

Conclusions:
The test item Thiolactic Acid 98/99% showed one or two exothermic effects, respectively, in the temperature range of 210 – 320 °C, with an average decomposition energy of approximately 220 J/g.
Executive summary:

The test itemThiolactic Acid 98/99%showed one or two exothermic effects, respectively, in the temperature range of 210 – 320 °C, with an average decomposition energy of approximately ‑220 J/g.

Description of key information

Up to 210°C no thermal effects could be observed.

Additional information

Justification for classification or non-classification

The test item is stable up to a temperature of 210°C.