Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02 Oct 2017 - 07 Dec 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Cross-reference
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Version / remarks:
2014
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Version / remarks:
1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7840 (Water Solubility)
Version / remarks:
1998
Deviations:
no
GLP compliance:
yes
Type of method:
column elution method

Test material

Constituent 1
Chemical structure
Reference substance name:
2-(2-thienyl)ethyl toluene-p-sulphonate
EC Number:
254-911-5
EC Name:
2-(2-thienyl)ethyl toluene-p-sulphonate
Cas Number:
40412-06-4
Molecular formula:
C13H14O3S2
IUPAC Name:
2-(thiophen-2-yl)ethyl 4-methylbenzene-1-sulfonate
Test material form:
solid: particulate/powder
Details on test material:
- Physical appearance: white to off-white powder
- Test item storage: at room temperature

Results and discussion

Water solubility
Key result
Water solubility:
11.3 mg/L
Conc. based on:
test mat.
Temp.:
20 °C
pH:
>= 6.4 - <= 6.5
Remarks on result:
other: average of two runs
Details on results:
Mean concentration in the water samples (n=10) obtained at the flowrate of 24 mL/h was 11.4 mg/L. CV= 1.1%.
Mean concentration in the water samples (n=10) obtained at the flowrate of 12 mL/h was 11.1 mg/L. CV= 0.71%.
The maximum difference on the mean values at both flow rates was ≤ 30% (i.e. 2.5%). Average of two runs: 11.3 mg/L.

The coefficient of variation (CV) (n=10) was ≤ 30% at both flow rates. It demonstrated that the system was in equilibrium at all flow rates. The maximum difference on the mean values at both flow rates was ≤ 30%.

Any other information on results incl. tables

No test substance was detected in the samples from the blank column.

Applicant's summary and conclusion

Conclusions:
The water solubility at 20°C was determined to be 11.3 mg/L.
Executive summary:

The water solubility of the substance was determined using the column elution method in a GLP study according to EC A.6, OECD 105 and OPPTS 830.7840.

Quantification was performed by UPLC-UV. The water solubility was calculated as the average of two runs (24 mL/h and 12 mL/h).

The water solubility at 20°C was determined to be 11.3 mg/L. The pH of the aqueous samples was 6.4-6.5.