Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 December 2017 to 21 December 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. certificate)
Type of method:
static method
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Sponsor and G316533
- Expiration date of the lot/batch: 25 March 2018
- Purity test date: 22 August 2017
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
3 Pa
Key result
Test no.:
#2
Temp.:
20 °C
Vapour pressure:
3 Pa
Conclusions:
The vapor pressure of the test substance was determined according to guideline criteria to be 3 Pa at 20 degrees Celsius.

Description of key information

The vapour pressure of the test substance was determined according to guideline criteria to be 3 Pa at 20 degrees Celsius.

Key value for chemical safety assessment

Vapour pressure:
3 Pa
at the temperature of:
20 °C

Additional information