Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Justification for type of information:
Specification data long held by the manufacturer. Practical handling experience has not resulted in the questioning of the accuracy of this data.
Qualifier:
equivalent or similar to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
288 °C
Atm. press.:
101.3 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The test substance demonstrated a flash point of 288 °C at 101.3 kPa in a closed-cup method.

Description of key information

288 °C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
288 °C

Additional information

Closed cup method