Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
before 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: DIN 51758
Version / remarks:
DIN 51758
Deviations:
not specified
Remarks:
estimation method applied
Principles of method if other than guideline:
no decision possible on the available data
GLP compliance:
not specified
Remarks:
DIN 51758
Type of method:
other: determination of flash point by Pensky-Martens closed tester
Remarks:
determination of flash point by Pensky-Martens closed tester
Flash point apparatus:
Abel-Pensky apparatus

Test material

Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: The test material is representative of the registered substance
- Expiration date of the lot/batch: not relevant
- Purity test date: not relevant

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room temperature in the dark
- Stability under test conditions: stable
- Solubility and stability of the test substance in the solvent/vehicle: soluble

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: none
- Preliminary purification step (if any): none

Results and discussion

Flash point
Key result
Flash point:
60 °C
Atm. press.:
ca. 1 Bar

Applicant's summary and conclusion

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
estimated flash point 60°C, experimental flash point study ordered
Executive summary:

Using an estimation according to DIN 51758, the flash point was estimated to be 60°C, and an experimental flash point study was ordered