Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04 November 2011 - 27 September 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
other: Metal block method

Test material

Constituent 1
Chemical structure
Reference substance name:
Disodium hexatitanate
EC Number:
815-182-4
Cas Number:
12058-75-2
Molecular formula:
Na2Ti6O13
IUPAC Name:
Disodium hexatitanate
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
Appearance: White powder
Storage conditions: Room temperature
Lot number: 1C96
Purity: 100%
Expiry date: 24 March 2014
Date received: 26 August 2011

Results and discussion

Melting / freezing point
Decomposition:
no
Sublimation:
no
Subl. temp.:
> 400 °C

Any other information on results incl. tables

In the initial examination, test substance did not melt, decompose or sublime when the temperature was increased to 400 °C. No further testing was therefore necessary.

Applicant's summary and conclusion

Conclusions:
The melting temperature of test substance was determined to be greater than 400 °C.