Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from the 13 of may 2017 to the 05 of July 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: UN Recommendations on the Transport of Dangerous Good, Manual of Tests and Criteria : test N4, Part III, sub-section 33.4.1.6
GLP compliance:
not specified
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch : 17025 25/26/28
- Expiration date of the lot/batch: 13 may 2020
- Manufacturing date: 13 may 2017
Strontium diacetate used as test item is hemihydrated
Remarks on result:
no self ignition observed under the test conditions
Remarks:
no exotherm occurs after >50h of thermal exposure.
Conclusions:
The test item has been tested according to the UN Recommendations on the Transport of Dangerous Good -Manual of Tests and Criteria (test N4, Part III, sub-section 33.4.1.6).
According to the guideline, the substance is not considered as self-heating substance as no self-ignition occured after >50h in a oven at 140°C.

Description of key information

The test item has been tested according to the UN Recommendations on the Transport of Dangerous Good -Manual of Tests and Criteria (test N4, Part III, sub-section 33.4.1.6).

According to the guideline, the substance is not considered as self-heating substance as no self-ignition occured  after >50h in a oven at 140°C.

Key value for chemical safety assessment

Additional information